With a wide range of fans in
the standard Fercell range there is a fan to suit every industrial
application, however Fercell has the flexibility to provide
bespoke units which meet customer’s special requirements.
Fercell fans are designed for tough industrial applications, featuring various
impeller-type designs and delivering optimum performance and efficiency. Standardisation,
using BS and European standard bearings, drives and seals ensuring easy maintenance. |
PADDLE BLADE FANS
 |
MV Range
The Fercell MV is a directly driven paddle bladed fan, designed
to withstand harsh industrial applications where the transportation
of heavy dust laden air is required.
The MV impellor is statically
and dynamically balanced for stable, vibration-free, operation.
There
are 6 models in the MV range, with pressure ranges from 160mm
W/G up to 220mmW/G and air handling volumes from 2700m³/h up
to 11,200m³/h. |
ModelsMV3
| MV4 | MV5 | MV7 | MV10 | MV15
K Range
 |
There are
7 models in the K range, with pressure ranges
from 285mm W/G up to 20mmW/G and air handling
volumes from 12,100m³/h up to 18,000m³/h.
The K range of belt driven paddle bladed fans, are designed to for the transportation
of air with a high percentage of large/heavy particles. The impeller is manufactured
from heavy gauge plate steel (incorporating stiffening bars on the larger models)
and is statically and dynamically balanced for stable, vibration-free, operation.
The belt driven formation enables numerous configurations of speed, pressure
and volume matching the fan exactly to the requirements of the application
|
Models30K
| 40K | 45K | 50K | 75K | T200K | T300K
BACKWARD BLADED FANS
 |
MVS
Range
The MVS backward bladed fan is designed for handling light/medium dust loads
in a wide variety of industrial and commercial applications. The direct drive
MVS has an aerodynamic inlet, which reduces noise levels and maintains high peak
efficiency.
The Fercell MVS impellor is statically and dynamically balanced for stable, vibration
free operation
There are 4 models in the MVS range, with pressure ranges from 285mm W/G up to
320mmW/G and air handling volumes from 12,100m³/h up to 18,000m³/h.
Standard construction material is heavy gauge formed steel, with a hardwearing
paint finish, however alternative materials and anti-corrosion finishes are available. |
ModelsMVS/HR15
| MVS/HR20 | MVS/HR25 | MVS/HR30
BIFURCATED FANS
 |
NTB
Range
Designed to perform in the most challenging applications, handling numerous types
of contaminated air, the direct drive NTB is reliable, economical and low maintenance.
Available with various motor, impellor and zone (EExd) options.
There are 8 models in the standard range, with pressure ranges from 400mm W/G
up to 2500mmW/G air handling volumes from 360m³/h up to 21,000m³/h.
|
Models150NTB
| 175NTB | 250NTB | 315NTB | 400NTB | 500NTB | 630NTB | 710NTB
MULTIVANE
FANS
 |
RP Range
The multi-vane forward curved fan design of the RP suits general ventilating
applications, handling clean/lightly loaded air. The RP is directly driven by
a range of T.E.F.C motors, with various speed options, and can be supplied for
hazardous applications demanding.
There are 9 models in the RP range, with pressure ranges from 85mm W/G up to
370mmW/G and air handling volumes from 930m³/h up to 24,200m³/h. |
ModelsRP250
| RP280 | RP310 | RP350 | RP400 | RP450 | RP500
| RP560 | RP630
AXIAL FLOW FANS
 |
Long
Case Axial Range
The LCA is a direct drive fan designed for transportation for clean air. The
drive is coupled directly to the impellor, with the motor located within the
air stream. The simple design is reliable, economic and easy to service.
Standard LCA impellor configuration has cast aluminium hubs with glass reinforced
polypropylene blades, with an operating temperature range of 40°C to 100°C.
There are 7 models in the standard LCA range, with air handling volumes from
2754m³/h up to 47,600m³/h. |
Models400
| 500 | 630 | 710 | 800 | 900 | 1000
Belt Driven Axial Range
 |
The Fercell BDA is designed for transportation
for clean/lightly loaded air where it is necessary for the
motor to be located away from the air stream. The BDA drive
train, including bearings, pulleys and belts are away from
the air stream, with only the impeller blades exposed.
Standard BDA impellor configuration has cast aluminium hubs with glass reinforced
polypropylene blades, with an operating temperature range of 40°C to 100°C.
For operating temperatures above 100°C, alternative materials are available.
|
There are 7 models in the standard BDA range, with air handling volumes
from 2754m³/h up to 47,600m³/h.
Models400
| 500 | 630 | 710 | 800 | 900 | 1000 BACKWARD BLADED AEROFOIL FANS
 |
MT
Range
The backward inclined blades and aerodynamic inlet design of the MT generate
high volumes of air whilst minimizing power consumption. Flexibility to configure
speed, pressure and volume is provided by the indirect drive coupling, matching
the fan characteristics to the application. Designed for handling clean or lightly
loaded air, the MT is quite running and maintains very high peak efficiency.
There are 8 models in the MT range, with pressure ranges from 285mm W/G up to
320mmW/G and air handling volumes from 12,100m³/h up to 18,000m³/h.
|
Standard construction material
is heavy gauge formed steel, with a hardwearing paint
finish, however alternative materials and anti-corrosion
finishes are available.
Models30MT
| 40MT | 50MT | 60MT | 70MT | 80MT | 90MT |100MT
ACCOUSTICS
 
|
Fercell also manufactures a wide range of acoustic solutions,
were the operational noise levels require reduction. Both
acoustic housings and in-line silencers can be supplied to
suit fan characteristics.
Utilising flexible connectors, anti-vibration pads and fire retardant sound absorbing
materials, Fercell's acoustic solutions maximise noise reductions.
For large fan units, Fercell’s acoustic housings incorporate a cool air
make-up system, where external air is drawn through the housing and across the
drive motor, extracting the motor generated warm air. |
|
|